NAME


detectups - UPS detection/powerd configuration generator

SYNOPSIS


/sbin/detectups [tty]

DESCRIPTION


detectups monitors the serial port connected to an UPS device and will attempt to determine the method of UPS notification of power outage. It will ask you to remove the power cord from the wall to the UPS, or push the UPS’s test button. It will then determine what all has happened and ask to generate a config file based on your UPS and cable configuration. detectups needs to watch a tty with modem control properties. Please refer to the powerd documentation for further information.

ARGUMENTS


Serial-Device Some serial port that is not being used by some other device, and does not share an interrupt with any other serial port. /etc/powerd.conf

FILES


/etc/powerd.conf        powerd configuration file that                                 detectups generates
/etc/inittab            init is what actually issues the                                 shutdown

SEE ALSO


powerd(8), shutdown(8), wall(1), inittab(5).

AUTHOR


James Brents <James@nistix.com> (with parts of this man page borrowed from all over the Linux community)